An engineer reconfi...
 
Notifications
Clear all

An engineer reconfigures the port-channel between SW1 and SW2 from an access port to a trunk and immediately notices this error in SW1's log:

1 Posts
1 Users
0 Likes
134 Views
(@cainsmarshall)
Posts: 692
Noble Member
Topic starter
 

Refer to the exhibit.

An engineer reconfigures the port-channel between SW1 and SW2 from an access port to a trunk and immediately notices this error in SW1's log:

*Mar 1 09:47:22.245: %PM-4-ERR_DISABLE: bpduguard error detected on Gi0/0, putting Gi0/0 in err-disable state

Which command set resolves this error?

  • A . SW1(config-if)#interface Gi0/0
    SW1(config-if)#no spanning-tree bpdufilter
    SW1(config-if)#shut
    SW1(config-if)#no shut
    B. SW1(config-if)#interface Gi0/0
    SW1(config-if)#no spanning-tree bpduguard enable
    SW1(config-if)#shut
    SW1(config-if)#no shut
    C. SW1(config-if)#interface Gi0/0
    SW1(config-if)#spanning-tree bpduguard enable
    SW1(config-if)#shut
    SW1(config-if)#no shut
    D. SW1(config-if)#interface Gi0/1
    SW1(config-if)#spanning-tree bpduguard enable
    SW1(config-if)#shut
    SW1(config-if)#no shut

Show Answer Hide Answer

Suggested Answer: B
 
Posted : 27/10/2022 4:18 am

Latest 350-401 V1 Dumps Valid Version

Latest And Valid Q&A | Instant Download | Once Fail, Full Refund
Share: